Labels:text | screenshot | font | number | parallel | line | black and white | receipt OCR: Quick Access Prefire Plan Building Address: 921 C Street Building Description: 260' X 100', 1-story, Ordinary Construction, common cockloft (This is the largest fire area in the complex) Roof Construction: Steel bar-joist, plywood sheathing, composition covering Floor Construction: Concrete slab Occupancy Type: Initial Resources Required: Mixed mercantile 3E, 1T, 1 Chief Hazards to Personnel: ********* Early roof collapse Location of Water Supply: Available Flow: Hydrants on every corner 5,000 gpm Estimated Fire Flow Level of Involvement 25% 50% 75% 100% Estimated Fire Flow 1325 2625 3950 5250 * Fire flow based on largest occupancy (Thrift Shop) 12500 sq.ft. with 1 exterior exposure. Fire Behavior Prediction: Possible extension into cockloft with further extension to other occupancies Predicted Strategies: Ventilation, Exposure Protection, Confinement Problems Anticipated: Traffic congestion during business hours, difficult access through doors on Side C. Standpipe: Sprinklers: Fire Detection: none none none